Ascent™-Max-Ductless-Fume-Hood-with-Secondary-Carbon-Filter-ADC-C-series

Login to See Prices

The Ascent™ Max Ductless Fume hood C-series has a secondary Carbon exhaust filter that offers a higher filtration efficiency against toxic chemical  fumes.

Key Benefits:

  • Certified to ASHRAE 110, EN 14175-3, AFNOR NF X 15-203, BS 7989, BS 7258
  • Robust hood construction for a long lasting unit.
  • Large working area provides user comfort.
  • Generous carbon filter weight to ensure uniformed filtration.
  • Elegant and smooth sliding sash window.
  • Isocide™ powder coating prevents surface contamination.
Add to Wishlist
Add to Wishlist

Description

PRODUCT FEATURES

  • Grade 304 stainless steel work top surface that will never rust, chip or generate particles.
  • Electrogalvanized steel wall for maximum durability
  • Lip at the front edge of work surface ensures that any spillage is contained in the work zone.
  • Sentinel™ microprocessor control system with audible and visual alarms for unsafe conditions.
  • Front service panel opens up easily for maintenance functions
  • Optional VOC sensor to monitor chemical concentration within the cabinet work zone.
  • All cabinet service and filter replacement can be carried out from the front, allowing the cabinet to be placed against wall in the laboratory to save space.
  • Over 8 different Nanocarb™ filter types to choose from: Volatile organic compounds, acid, mercury, sulfur, halogen, aldehyde, ammonia or ethers/chloroform.

 

MODELS

Guide to Models (Ascent Max Series)
ADC   – 4     C    1
External WidthCodeModelCodeElectricalCode
28.7″ (2ft.)  2*ADC-B-standard modelB220-240 VAC , 50 Hz1
40.7″ (3ft.)3ADC-C-has a secondary carbon filterC110-220 VAC , 60 Hz2
52.8″ (4ft.)4ADC-D-standard model + Transparent Back wallD220-240 VAC , 60 Hz3
64.8″ (5ft.)5ADC-E- has a secondary HEPA filterE
76.8″ (6ft.)6

*2 ft. fume hood is only available for ADC-B models.
ADC-_B/C/D/E_-PP –with Swan neck faucet and PP sink provision

 

Model220-240 VAC,
50 Hz
ADC-3C1ADC-4C1ADC-5C1ADC-6C1
ADC-3C1-PPADC-4C1-PPADC-5C1-PPADC-6C1-PP
110-120 VAC,
60 Hz
ADC-3C2ADC-4C2ADC-5C2ADC-6C2
ADC-3C2-PPADC-4C2-PPADC-5C2-PPADC-6C2-PP
220-240 VAC,
60 Hz
ADC-3C3ADC-4C3ADC-5C3ADC-6C3
ADC-3C3-PPADC-4C3-PPADC-5C3-PPADC-6C3-PP
Nominal Size0.9 meter (3′)1.2 meter (4′)1.5 meter (5′)1.8 meter (6′)
External Dimensions
( W x D x H)
1035 x 736 x 1455 mm
40.7” x 29.0” x 57.3”
1340 x 736 x 1455 mm
52.8” x 29.0” x 57.3”
1645 x 736 x 1455 mm
64.8” x 29.0” x 57.3”
1950 x 736 x 1455 mm
76.8” x 29.0” x 57.3”
Internal work area
( W x D x H)
965 x 596 x 765 mm1268 x 596 x 765 mm1575 x 596 x 765 mm1880 x 596 x 765 mm
38.0” x 23.5” x 30.1”50.0” x 23.5” x 30.1”62.0” x 23.5” x 30.1”74.0” x 23.5” x 30.1”
Airflow velocity (inflow)0.4 m/s